Optimization of solid needles for percutaneous needle electrolysis in invasive physiotherapy: ex vivo study
You have full access to this open access article
Downloads
Abstract
Introduction: Percutaneous needle electrolysis (PNE) is an invasive physiotherapy technique that applies a galvanic current through a solid needle to treat musculoskeletal disorders. The effectiveness of the technique depends on the properties of the needle used, including its conductivity, biocompatibility, and mechanical resistance. This study explores improvements in needle design to enhance therapeutic outcomes.
Materials and Methods: The research focuses on the evaluation of different needle materials and coatings to optimize electrical conductivity and minimize tissue damage. Experimental analysis includes testing mechanical properties, corrosion resistance, and electrical performance. The results of this study can also be applied to patient safety and comfort.
Results: Findings indicate that modifications in needle material, such as the use of stainless steel with specialized coatings, significantly improve electrical efficiency and reduce unwanted oxidation. Enhanced designs result in lower resistance, improving the precision of the electrical current application. Additionally, improvements in needle flexibility and sharpness may contribute to reducing patient discomfort.
Conclusions: The study confirms that improving the material and coating of solid needles used in PNE can improve the technique's effectiveness. Specifically, stainless steel needles with specialized coatings increase electrical conductivity, reduce oxidation, and improve durability. These modifications allow for more precise current application, minimizing tissue damage and potentially reducing patient discomfort. Future studies should focus on clinical validation and further optimization to maximize safety and therapeutic benefits.
Keywords
- Percutaneous needle electrolysis (PNE)
- Solid Needles
- Invasive Physiotherapy
- Electrotherapy
- Needle Optimization
- Galvanic Current
- Musculoskeletal Treatment
References
Bosque M, Rhys L, Poveda E, Guerra R, Santafé MM. Alteración de las puntas de las agujas por la técnica de punción seca. Rev Fisioter Invasiva. 2016, 1(1): 26–34. https://www.elsevier.es/en-revista-journal-invasive-techniques-in-physical-212-pdf-X2386458316614031
Steen JP, Jaiswal KS, Kumbhare D. Myofascial Pain Syndrome: An Update on Clinical Characteristics, Etiopathogenesis, Diagnosis, and Treatment. Muscle Nerve. 2025 May;71(5):889-910. doi: 10.1002/mus.28377. DOI: https://doi.org/10.1002/mus.28377
Abat F, Gelber PE, Polidori F, Monllau JC, Sanchez-Ibañez JM. Clinical results after ultrasound-guided intratissue percutaneous electrolysis (EPI®) and eccentric exercise in the treatment of patellar tendinopathy. Knee Surg Sports Traumatol Arthrosc. 2015 Apr;23(4):1046-52. doi: 10.1007/s00167-014-2855-2. DOI: https://doi.org/10.1007/s00167-014-2855-2
Rios A. “El secreto de Rafa Nadal,” Perarnau Mag., 2013. Available: https://www.martiperarnau.com/el-secreto-de-rafa-nadal/
Minaya Muñoz F, Valera Garrido F, Sanchez-Ibañez JM. Uso de la Electrólisis Percutánea Intratisular (EPI®) en la Epicondilagia Crónica: Caso clínico. Fisioter calid vida, 211, 14(1): 13–16. ISSN 1575-4847
Gómez-Chiguano GF, Navarro-Santana MJ, Cleland JA, Arias-Buría JL, Fernández-de-Las-Peñas C, Ortega-Santiago R, Plaza-Manzano G. Effectiveness of Ultrasound-Guided Percutaneous Electrolysis for Musculoskeletal Pain: A Systematic Review and Meta-Analysis. Pain Med. 2021;22(5):1055-1071. doi: 10.1093/pm/pnaa342.. DOI: https://doi.org/10.1093/pm/pnaa342
Easytech, "Physio INVASIVA 2.0 Manual de usuario." Borgo San Lorenzo:easytech, pp.1-66, 2021.
Quimica.es, Parafina..Available: https://www.quimica.es/enciclopedia/Parafina.html.
Aceitedegirasol.es. Elaboración del Aceite de Girasol. Available: http://www.aceitedegirasol.es/elaboracion-aceite-de-girasol.html.
Agencia española del medicamento. rospecto_Apiroserum Solución Ringer solución para perfusión. Barcelona, 2016.
Leica Microsystems. Sistema de microscopio digital Leica DMS300. Available: https://www.leica-microsystems.com/es/productos/microscopios-digitales/detalles/leica-dms300/, 2022.
Que es y como funciona el microscopio electronico de barrido. Available: https://www.equiposylaboratorio.com/portal/articulo-ampliado/que-es-y-como-funciona-el-microscopio-electronico-de-barrido.
URV, Microscopía electrónica de rastreo ambiental (ESEM). Available: https://www.urv.cat/es/investigacion/apoyo/recursos-cientificos-tecnicos/serveis/esem/.
Freire CE. Fundamento biofísico de la exploración ecográfica. Sitio Argentino Prod. Anim., 2004, pp. 1–6.
Margalef R, Bosque M, Minaya-Muñoz F, Valera-Garrido F, Santafe MM. Safety analysis of percutaneous needle electrolysis: a study of needle composition, morphology, and electrical resistance. Acupunct Med. 2021;39(5):471-477. doi: 10.1177/0964528420988007 DOI: https://doi.org/10.1177/0964528420988007
Valera Garrido F, Minaya Muñoz F. Fisioterapia Invasiva. 1ª ed. Barcelona: Elsevier; 2013. Capítulo 9: Mecanismos moleculares de la electrolisis percutánea intratisular; 187–203
Downloads
License
Copyright (c) 2025 Cesar Suárez Malanda, Manel Santafe

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.